Описание товара
Подробности
The GLS-ODT-C-NS is a low-profile, ceiling-mount occupancy sensor that delivers a powerful and cost-effective solution for reducing energy costs and enhancing the functionality of standalone lighting systems. It is designed for large areas up to 2000 square feet to detect when the room is occupied, making it great for use in large spaces such as auditoriums, warehouses, and building lobbies. Dual-technology motion sensing, available with the GLS-ODT-C-NS, affords extreme reliability for control of lighting, climate control, and other devices in the room. For power and control, the GLS-ODT-C-NS can connect directly to a GLPP, GLPAC, or GL-IPAC-SW8. The GLS-SIM Sensor Integration Module gives the option to interface with a control system via Cresnet®.
Дополнительная информация
Sensing | ||
Sensor Technology | Passive Infrared and Ultrasonic (40 kHz) | |
Coverage Area | 2000 sq. ft. | |
Coverage Pattern | 360 degrees | |
LED Indicators | ||
IR | (1) Red LED, PIR detection | |
Ultrasonic | (1) Green LED, Ultra Sonic detection | |
IR Remote (sold separately) | ||
Parameters and settings available through IR remote: Separate Occupancy and Vacancy sensitivity settings; Timeout (30s, 2m, 5m, 10m, 15m, 30m); Walk-Through mode “Short Timeout” (Enable/Disable); LEDs (Enable/Disable); PIR Sensitivity (High, Med, Low, OFF), with the option to set separate occupancy and vacancy settings; US Sensitivity (High, Med, Low, OFF), with the option to set separate occupancy and vacancy settings; US detection (Side A only, Side B only, Both); Factory Reset; Force Vacancy; 4 Custom buttons (for future additional features) | ||
Connections | ||
(1) 5-pin 3.5mm detachable terminal block; 16 AWG maximum wire width supported, includes the following terminals: | ||
+24V | DC power input | |
OCC | Occupancy sensor control signal output; provides 24 Volts DC high logic signal when occupancy is detected (both PIR and US must sense occupancy to provide 24 V signal, if room is transitioning from a vacant to occupied state; after initial occupancy is detected, either PIR or US detection will trigger the 24 V signal to maintain the occupied state); Short circuit protected; Connects to a GLS-SIM Integration Module (sold separately) on any Crestron® control system | |
NC | Unused | |
G | Ground | |
IR | IR single direction, transmits information read from remote by IR receiver on sensor | |
Environmental | ||
Temperature | 32° to 104°F (0° to 40°C) | |
Humidity | 10% to 90% RH (non-condensing) | |
Power Requirements | ||
Current Consumption | 45 mA @ 24 Volts DC | |
Cresnet® Power Usage | 1 Watt | |
Enclosure | ||
Housing | Plastic, white | |
Mounting | Mounts to a 4” (102 mm) octagon box or ~3-1/2” (88 mm) diameter hole created by provided cutout template. Includes mounting screws and integral toggle clamps. A 1-1/2” (38 mm) minimum mounting depth is recommended. | |
Dimensions | ||
Diameter | 4.80 in (122 mm) | |
Depth | 2.30 in (59 mm) overall, 0.97 in (25 mm) exposed | |
Weight | ||
5.1 oz (144 g) | ||
Standards & Certifications | ||
UL60730-1, FCC, CE, C-Tick, IC, Plenum Rated, California Title 24 Code |